        (1)notice of readiness to carry out performance test:when the supplier considers that the contract plant is ready for theperformance test and that all of the conditions stated in paragraph 4.2above have been fulfilled, then he shall give the buyer a notice ofreadiness to carry out the performance test.within _________ hours of the receipt of such notice, the buyer shall;(a)acknowledge that the contract plant is ready for the performancetest to be conducted, or(b)submit to the supplier a written statement setting forth in whichrespects the contract plant is not ready for such performance test.if the buyer considers that contract plant is not ready, then he shallspecify in writing the conditions preventing the start of the performancetest. the party who is responsible for such conditions shall rectify thedefault.the performance test shall be commenced as soon as the aboveconditions are corrected.
        (2)performance test run:the performance test shall extend continuously over a (_________) hour period.
        (3)two or more units:where the contract plant includes two or more individual process unitsfor which separate process performance guarantees are to be demonstrated,the performance test may be carried out individually on each of the unitsor simultaneously with any other unit or units.
        (4)buyer's personnel:the performance test shall be carried out by the buyer's operatingpersonnel according to the instructions set forth in the supplieroperating manual and under the technical services of the supplier'sengineer.
        (5)interruption of performance test due to supplier:if the performance test run is interrupted because of failure of thesupplier, the performance test shall be repeated. the results obtainedduring such an interrupted operation shall not be used for evaluation ofthe performance test.
        (6)interruption of performance test due to buyer:if the performance test is interrupted because of failure of the buyerto comply with any of the conditions set forth in this appendix 5 (processperformance guarantees)and any other parts of the agreement or because ofimproper maintenance or operation on the part of the buyer, theperformance test shall be repeated but if it had been running for morethan _________ hours then the duration of the performance test before theinterruption may be credited to the performance test period and theresumed performance test will be continued for the remainder of theperformance test period.